|
|
Study of different radial artery puncture spots under ultrasound guidance |
ZHAO Xiaobao1 SHAO Xinfeng1▲ DING Yanling1 QUAN Zhefeng2 |
1.Department of Anesthesiology, Baoding First Central Hospital, Hebei Province, Baoding 071000, China;
2.Department of Anesthesiology, Beijing You’an Hospital, Capital Medical University, Beijing 100069, China |
|
|
Abstract Objective To explore the choice of ideal puncture spot for radial artery puncture under ultrasound guidance. Methods A total of 120 patients with radial artery puncture under ultrasound guidance in Baoding First Central Hospital, Hebei Province, and Beijing You’an Hospital, Capital Medical University from June 2019 to January 2021 were selected as the study subjects. According to random number table method, they were divided into routine group (group A, 60 cases) and specific depth group (group B, 60 cases). In group A, conventional ultrasound guidance radial artery puncture was performed. In group B, the projection point on the surface of the radial artery with radius artery depth half the distance from the short axis of the ultrasonic probe was used as the puncture spot. Both groups were punctured by short axis plane method with ultrasonic probe. The primary outcome was the success rate of the first puncture, and the secondary outcome included puncture failure rate and complication rate. Results The success rate of first puncture in group B was higher than that in group A, and the difference was statistically significant (P < 0.05); there was no significant difference in puncture failure rate between two groups (P > 0.05). There were no significant differences in the incidence of hemorrhage and hematoma between two groups (P > 0.05). No serious complications such as thrombus and arterial occlusion occurred in two groups. Conclusion It is an optimal choice to select the radial artery at half the depth of the short axis of the ultrasonic probe as the puncture spot when performing radial artery puncture under the short axis plane method with ultrasonic probe.
|
|
|
|
|
[1] Genre Grandpierre R,Bobbia X,Muller L,et al. Ultrasound guidance in difficult radial artery puncture for blood gas analysis:A prospective,randomized controlled trial [J]. PLoS One,2019,14(3):e0213683.
[2] Zhefeng Q,Luo C,Zhang L,et al. Application of Optimized Ultrasonic Localization System for Radial Artery Puncture by Intern Doctors:A Randomized Trial [J]. Med Sci Monit,2019,28(25):1566-1571.
[3] 郝帅,池萍,贺海丽,等.超声引导下双线定位技术在桡动脉穿刺中的应用[J].中国医药导报,2020,17(1):119-121.
[4] Aouad-Maroun M,Raphael CK,Sayyid SK,et al. Ultrasound-guided arterial cannulation for paediatrics [J]. Cochrane Database Syst Rev,2016,9:CD011364.
[5] Cao L,Zhang L,Ai M,et al. Application of radial arterial puncture cannulation under ultrasonic guidance in patients with critical diseases [J]. Zhong Nan Da Xue Xue Bao Yi Xue Ban,2018,43(4):447-451.
[6] 安慎通,熊利泽,孙绪德,等.国产无创瞬时血压连续监护仪监测术中血压的有效性和准确性[J].中华麻醉学杂志,2019,39(5):598-601.
[7] Nakayama Y,Nakajima Y,Sessler DI,et al. A novel method for ultrasound-guided radial arterial catheterization in pediatric patients [J]. Anesth Analg,2014,118(5):1019-1026.
[8] Li X,Fang G,Yang D,et al. Ultrasonic Technology Improves Radial Artery Puncture and Cannulation in Intensive Care Unit(ICU)Shock Patients [J]. Med Sci Monit,2016,22:2409-2416.
[9] Chao L,Zhi M,Kang H,et al. Comparison between the long-axis/in-plane and short-axis/out-of-plane approaches for ultrasound-guided vascular catheterization:an updated meta-analysis and trial sequential analysis [J]. Ther Clin Risk Manag,2018,14:331-340.
[10] 姚雷,宋杰,赵露林,等.心肺转流下心脏瓣膜置换术患者TNF-α和8-isoPGF2α浓度与术后ARDS相关性研究[J].临床麻醉学杂志,2020,36(3):217-222.
[11] Rastogi A,Agarwal A,Goyal P,et al. Ultrasound guided internal jugular vein cannulation in infants:Comparative evaluation of novel modified short axis out of plane approach with conventional short axis out of plane approach [J]. Indian J Anaesth,2018,62(3):208-213.
[12] Gopalasingam N,Hansen MA,Thorn S,et al. Ultrasound-guided radial artery catheterisation increases the success rate among anaesthesiology residents:a randomised study [J]. J Vasc Access,2017,18(6):546-551.
[13] 韩丁,魏国,欧阳川,等.门静脉高压患儿围术期血流动力学的变化[J].临床麻醉学杂志,2019,35(8):755-758.
[14] Quan ZF,Zhang L,Zhou C,et al. Acoustic Shadowing Facilitates Ultrasound-guided Radial Artery Cannulation in Young Children [J]. Anesthesiology,2019,131(5):1018-1024.
[15] Kiberenge RK,Ueda K,Rosauer B. Ultrasound-Guided Dynamic Needle Tip Positioning Technique Versus Palpation Technique for Radial Arterial Cannulation in Adult Surgical Patients:A Randomized Controlled Trial [J]. Anesth Analg,2018,126(1):120-126.
[16] Burad J,Date R,Kodange S,et al. Comparison of conventional and ultrasound guided techniques of radial artery cannulation in different haemodynamic subsets:a randomised controlled study [J]. Intensive Care Med,2017, 43(1):140-141.
[17] Song IK,Choi JY,Lee JH,et al. Short-axis/out-of-plane or long-axis/in-plane ultrasound-guided arterial cannulation in children:A randomised controlled trial [J]. Eur J Anaesthesiol,2016,33(7):522-527.
[18] 王雪婷,高雪花,曹雯,等.血乳酸联合中心静脉-动脉血二氧化碳分压差与动脉-中心静脉血氧含量差比值预测脓毒性休克患者预后的应用价值[J].中华危重病急救医学,2020,32(1):39-43.
[19] Quan ZF,Tian M,Chi P,et al. Modified short-axis out-of-plane ultrasound versus conventional long-axis in-plane ultrasound to guide radial artery cannulation:a randomized controlled trial [J]. Anesth Analg,2014,119(1):163-169.
[20] Takeshita J,Yoshida T,Nakajima Y,et al. Ynamic Needle Tip Positioning for Ultrasound-Guided Arterial Catheterization in Infants and Small Children With Deep Arteries:A Randomized Controlled Trial [J]. J Cardiothorac Vasc Anesth,2019,33(7):1919-1925.
[21] 郝帅,贺海丽,李颖,等.新型婴幼儿桡动脉穿刺技术在临床中的应用[J].中国医药导报,2019,16(27):93-96.
[22] Liu L,Tan Y,Li S,et al. “Modified Dynamic Needle Tip Positioning” Short-Axis,Out-of-Plane,Ultrasound-Guided Radial Artery Cannulation in Neonates:A Randomized Controlled Trial [J]. Anesth Analg,2019,129(1):178-183.
[23] Nam K,Jeon Y,Yoon S,et al. Ultrasound-guided radial artery cannulation using dynamic needle tip positioning versus conventional long-axis in-plane techniques in cardiac surgery patients:a randomised,controlled trial [J]. Minerva Anestesiol,2020,86(1):30-37.
[24] 高珊珊,刘华献.超声引导小儿桡动脉穿刺置管术对小儿患者穿刺成功率及安全性的影响[J].中国现代医生,2020,58(30):127-130. |
|
|
|