Research progress of chest CT low-dose scanning combined with different iterative reconstruction |
SU Yuwen1 LIU Hui2 DENG Kai1 |
1.Department of Radiology, the First Affiliated Hospital of Shandong First Medical University Shandong Provincial Qianfoshan Hospital, Shandong Province, Ji’nan 250014, China;
2.School of Computer Science and Technology, Shandong University of Finance and Economics, Shandong Province, Ji’nan 250014, China |
|
|
Abstract CT enhanced examination is widely used in clinical practice as a routine examination item for chest diseases, which also makes CT the main source of iatrogenic radiation. Among the commonly used CT post-processing algorithms, the iterative reconstruction algorithm can reduce the contrast agent dose and radiation dose by adjusting the scan weight, while obtaining images that meet the needs of clinical diagnosis. There is still no uniform standard for how to choose the optimal scan weight. This article mainly reviews the development process, basic principles and clinical applications of chest CT low-dose scanning combined with iterative reconstruction, in order to provide a reference for reasonable reduction of the radiation dose of CT scanning to patients and medical staff.
|
|
|
|
|
1] Schernthaner RE,Haroun RR,Nguyen S,et al. Characteristics of a New X-Ray Imaging System for Interventional Procedures:Improved Image Quality and Reduced Radiation Dose [J]. Cardiovasc Intervent Radiol,2018,41(3):502-508.
[2] Yurt A,?魻zsoykal ■,Obuz F. Effects of the Use of Automatic Tube Current Modulation on Patient Dose and Image Quality in Computed Tomography [J]. Mol Imaging Radionucl Ther,2019,28(3):96-103.
[3] Ortiz López P. Eight decades of ICRP recommendations in medicine:a perspective [J]. Ann ICRP,2016,45(1 Suppl):106-112.
[4] Mousavi-Gazafroudi SS,Sajjadieh-Khajouei A,Moradi M,et al. Evaluation of image quality and radiation dose in low tube voltage coronary computed tomography angiography [J]. ARYA Atheroscler,2019,15(5):205-210.
[5] Spearman JV,Schoepf UJ,Rottenkolber M,et al. Effect of Automated Attenuation-based Tube Voltage Selection on Radiation Dose at CT:An Observational Study on a Global Scale [J]. Radiology,2016,279(1):167-174.
[6] 程香,何玲,陈欣.双低扫描技术在儿童腹部增强CT中的应用研究[J].临床放射学杂志,2020,39(5):988-993.
[7] 李鹤.低管电压、低浓度对比剂联合ASiR-V技术用于冠状动脉CT成像的临床研究[D].长春:吉林大学,2018.
[8] 陈浩,袁子龙,张照喜,等.“双低”技术在胸部CT增强扫描中的可行性研究[J].中国中西医结合影像学杂志,2018, 16(4):348-351.
[9] 王祺,马荣希,李晓辉.多层螺旋CT双低剂量扫描在肺动脉CTA中的应用研究[J].河北医药,2015,37(24):3735-3737.
[10] Haji-Momenian S,Ellenbogen A,Khati N,et al. Comparing Dose-Length Product-Based and Monte Carlo Simulation Organ-Based Calculations of Effective Dose in 16- and 64-MDCT Examinations Using Automatic Tube Current Modulation [J]. AJR Am J Roentgenol,2018, 210(3):583-592.
[11] Martin CJ,Sookpeng S. Setting up computed tomography automatic tube current modulation systems [J]. J Radiol Prot,2016,36(3):R74-R95.
[12] 贾楠,王新江,惠萍,等.适应性统计迭代重建技术降低胸部CT扫描剂量的初步临床研究[J].中国医学影像学杂志,2010,18(6):551-553.
[13] 王立环,顾文豪,丁佐运,等.前置自适应统计迭代重建技术对胸部CT平扫的辐射剂量及图像质量的影响[J].实用放射学杂志,2019,35(1):122-125.
[14] Kwon H,Cho J,Oh J,et al. The adaptive statistical iterative reconstruction-V technique for radiation dose reduction in abdominal CT:comparison with the adaptive statistical iterative reconstruction technique [J]. Br J Radiol,2015,88(1054):20150463.
[15] Goodenberger MH,Wagner-Bartak NA,Gupta S,et al. Computed Tomography Image Quality Evaluation of a New Iterative Reconstruction Algorithm in the Abdomen (Adaptive Statistical Iterative Reconstruction-V) a Comparison With Model-Based Iterative Reconstruction,Adaptive Statistical Iterative Reconstruction,and Filtered Back Projection Reconstructions [J]. J Comput Assist Tomogr,2018,42(2):184-190.
[16] 张喜荣,贺太平,贾永军,等.低辐射剂量下FBP、ASIR和ASIR-V 3种不同重建算法对上腹部CT图像质量的影响[J].中国中西医结合影像杂志,2020,18(3):305-308.
[17] 张卓璐,刘卓,綦维维,等.基于多模型的迭代重建算法在胸部低剂量CT筛查中的应用[J].中国介入影像与治疗学,2015,12(11):691-695.
[18] Moser JB,Sheard SL,Edyvean S,et al. Radiation dose-reduction strategies in thoracic CT [J]. Clin Radiolm,2017,72(5):407-420.
[19] Afadzi M,Lysvik EK,Andersen HK. Ultra-low dose chest computed tomography:Effect of iterative reconstruction levels on image quality [J]. Eur J Radiol,2019,114:62-68.
[20] Tang H,Yu N,Jia Y,et al. Assessment of noise reduction potential and image quality improvement of a new generation adaptive statistical iterative reconstruction (ASIR-V) in chest CT [J]. Br J Radiol,2018,91:20170521.
[21] 李莹,艾娜娜,张颖颖,等.前置自适应统计迭代重建技术对体模肺纯磨玻璃结节图像质量及辐射剂量的影响[J].中国医学影像技术,2018,34(5):775-778.
[22] 颜利辉,陈飞,姚立正,等.前置自适应统计迭代重建技术对胸部CT辐射剂量和图像质量的影响:体模与临床研究[J].中国医学影像技术,2017,33(3):468-472.
[23] 许佳佳,张艳,赵强,等.全模型实时自适应迭代重建技术在胸部扫描中的临床应用[J].中国医学装备,2020, 17(9):77-81.
[24] 于卫永,孙晓楠.ASiR-V联合70 kV个性化轴扫对老年慢性阻塞性肺疾病患者伴肺炎的诊断作用[J].中国老年学杂志,2020,40(4):788-791.
[25] 丁婕,何维恒,杨利莉,等.ASiR-V联合70 kV个性化轴扫在小儿肺炎CT扫描中的可行性探究[J].中国临床医学影像杂志,2018,29(7):475-478.
[26] Patz EF Jr,Greco E,Gatsonis C,et al. Lung cancer incidence and mortality in National Lung Screening Trial participants who underwent low-dose CT prevalence screening:a retrospective cohort analysis of a randomised,multicentre,diagnostic screening trial [J]. Lancet Oncol,2016,17(5):590-599.
[27] 杨德盛.肺部单发磨玻璃结节MSCT征象对良恶性结节的鉴别诊断价值[J].影像研究与医学应用,2018,2(23):190-192.
[28] Tang H,Liu Z,Hu Z,et al. Clinical value of a new generation adaptive statistical iterative reconstruction (ASIR-V) in the diagnosis of pulmonary nodule in low-dose chest CT [J]. Br J Radiol,2019,92(1103):20180909.
[29] 曾凡学,张振明,董险峰,等.小剂量对比剂CT肺动脉造影诊断肺动脉栓塞的临床价值分析[J].中国医学装备,2021(1):56-60.
[30] Meier A,Higashigaito K,Martini K,et al. Correction:Dual Energy CT Pulmonary Angiography with 6 g Iodine-A Propensity Score-Matched Study [J]. PLoS One,2017,12(2):e0172251. |
|
|
|