Research progress on measurement methods of tibial prosthesis rotation angle after total knee arthroplasty |
DING Chuan DENG Jiang |
Department of Joint Surgery, the Third Affiliated Hospital of Zunyi Medical University, Guizhou Province, Zunyi 563000, China |
|
|
Abstract Total knee arthroplasty (TKA) is currently the fastest and most effective method for the treatment of end-stage knee osteoarthritis, and the rotation angle of the tibial prosthesis is an important factor in determining its clinical efficacy, and it is also the of important evaluation index clinical efficacy after TKA. Although scholars at home and abroad are based on commonly used imaging techniques such as X-ray, 2D-CT, 3D-CT or MRI, refer to the anatomical landmarks such as posterior edge of tibial prosthesis, tibial tubercle, medial third of tibial tubercle, patellar tendon, Akagi line, reported that the Beger scheme, Mayo scheme, CTTT distance and PLCL technology can accurately assess the rotation angle of tibial prosthesis after TKA, but there is still no gold standard which is method recognized to measure the rotation angle of tibial prosthesis. This article summarizes the measurement methods of the rotation angle of the posterior tibial prosthesis in TKA, aiming to provide reference for the joint surgeon in choosing the measurement method of the rotation angle of the posterior tibial prosthesis in TKA and further research on the optimal angle of the tibial prosthesis rotation in TKA.
|
|
|
|
|
[1] Chen TM,Chen YH,Sun HS,et al. Fibroblast growth factors:Potential novel targets for regenerative therapy of osteoarthritis [J]. Chin J Physiol,2019,62(1):2-10.
[2] Skou ST,Roos EM,Laursen MB,et al. Total knee replacement and non-surgical treatment of knee osteoarthritis:2-year outcome from two parallel randomized controlled trials [J]. Osteoarthr Cartil,2018,26(9):1170-1180.
[3] Pua YH,Poon CLL,Seah FJT,et al. Predicting individual knee range of motion,knee pain,and walking limitation outcomes following total knee arthroplasty [J]. Acta Orthop,2019,90(2):179-186.
[4] 刘锴.胫骨假体旋转对线技术影响髌股关节生物力学的作用机制[J].中国组织工程研究,2016,20(22):3301-3307.
[5] de Valk EJ,Noorduyn JCA,Mutsaerts ELAR. How to assess femoral and tibial component rotation after total knee arthroplasty with computed tomography:a systematic review [J]. Knee Surg Sports Traumatol Arthrosc,2016,24(11):3517-3528.
[6] 蔡飞,刘志斌,张宁,等.TKA中胫骨旋转力线定位方法的研究进展[J].现代中西医结合杂志,2016(4):450-452, 453.
[7] Berger RA,Rubash HE,Seel MJ,et al. Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis [J]. Clin Orthop Relat Res,1993,10(286):40-47.
[8] Jazrawi LM,Birdzell L,Kummer FJ,et al. The accuracy of computed tomography for determining femoral and tibial total knee arthroplasty component rotation [J]. Arthroplasty,2000,15(6):761-766.
[9] Bédard M,Vince KG,Redfern J,et al. Internal Rotation of the Tibial Component is Frequent in Stiff Total Knee Arthroplasty [J]. Clin Orthop Relat Res,2011,469(8):2346-2355.
[10] Saffi M,Spangehl MJ,Clarke HD,et al. Measuring Tibial Component Rotation Following Total Knee Arthroplasty:What Is the Best Method? [J]. J Arthroplasty,2019,34(7):S355-S360.
[11] Mahmood FF,Holloway NJ,Deakin AH,et al. A new landmark for measuring tibial component rotation after total knee arthroplasty [J]. Knee,2019,26(3):779-786.
[12] Roper GE,Bloemke AD,Roberts CC,et al. Analysis of Tibial Component Rotation Following Total Knee Arthroplasty Using 3D High Definition Computed Tomography [J]. J Arthroplasty,2013,28(8):106-111.
[13] Hirschmann MT,Iranpour F,Konala P,et al. A novel standardized algorith for evaluating patients with painful total knee arthroplasty using combined single photon emission tomography and conventional computerized tomography [J]. Knee Surg Sports Traumatol Arthrosc,2010, 18(7):939-944.
[14] Rossi R,Bruzzone M,Bonasia DE,et al. Evaluation of tibial rotational alignment in total knee arthroplasty:a cadaver study [J]. Knee Surg Sports Traumatol Arthrosc,2010,18(7):889-893.
[15] Fang CH,Cheng CK,Qu TB,et al. The Posterolateral Corner-Locked Technique Is Applicable in a Chinese Population Regarding the Tibial Component Rotation Alignment in Total Knee Arthroplasty [J]. J Knee Surg,2020,33(5):466-473.
[16] Takai S,Yoshino N,Isshiki T,et al. Kneeling view:a new roentgenographic technique to assess rotational deformity and alignment of the distal femur [J]. J Arthroplasty,2003,18(4):478-483.
[17] Kanekasu K,Kondo M,Kadoya Y. Axial radiography of the distal femur to assess rotational alignment in total knee arthroplasty [J]. Clin Orthop Relat Res,2005,434(434):193-197.
[18] Pedraza W,Beckmann J,Mayer C,et al. Partially loaded plain radiographic measurement to evaluate rotational alignment in total knee arthroplasty [J]. Int Orthop,2016, 40(12):2519-2526.
[19] Hirschmann MT,Moser LB,Amsler F,et al. Phenotyping the knee in young non-osteoarthritic knees shows a wide distribution of femoral and tibial coronal alignment [J]. Knee Surg Sports Traumatol Arthrosc,2019, 27(5):1385-1393.
[20] Murakami AM,Hash TW,Hepinstall MS,et al. MRI evaluation of rotational alignment and synovitis in patients with pain after total knee replacement [J]. J Bone Joint Surg Br,2012,94(9):1209-1215.
[21] Heyse TJ,Tibesku CO. Improved femoral component rotation in TKA using patient specific instrumentation [J]. Knee,2014,21(1):268-271.
[22] Heyse TJ,Stiehl JB,Tibesku CO,et al. Measuring tibial component rotation of TKA in MRI:What is reproducible? [J]. Knee,2015,22(6):604-608.
[23] Sgroi M,Faschingbauer M,Javaheripour-Otto K,et al. Can rotational alignment of total knee arthroplasty be measured on MRI? [J]. Arch Orthop Trauma Surg,2015, 135(11):1589-1594.
[24] Heyse TJ,El-Zayat Bilal F,De Corte R,et al. Internal femoral component malrotation in TKA significantly alters tibiofemoral kinematics [J]. Knee Surg Sports Traumatol Arthrosc,2018,26(6):1767-1775.
[25] Koff Matthew F,Burge Alissa J,Potter Hollis G. Clinical magnetic resonance imaging of arthroplasty at 1.5 T [J]. J Orthop Res,2020,38(7):1455-1464.
[26] Rasch H,Falkowski AL,Forrer F,et al. 4D-SPECT/CT in orthopaedics:a new method of combined quantitative volumetric 3D analysis of SPECT/CT tracer uptake and component position measurements in patients after total knee arthroplasty [J]. Skeletal Radiol,2013,42(9):1215-1223.
[27] Wakelin EA,Tran L,Twiggs JG,et al. Accurate determination of post-operative 3D component positioning in total knee arthroplasty:the AURORA protocol [J]. J Orthop Surg Res,2018,13(1):275.
[28] Nardi C,Buzzi R,Molteni R,et al. The role of cone beam CT in the study of symptomatic total knee arthroplasty (TKA):a 20 cases report [J]. Br J Radiol,2017,90(1074):20160925.
[29] V?觟llner F,Weber T,Weber M,et al. A simple method for determining ligament stiffness during total knee arthroplasty in vivo [J]. Sci Rep,2019,9(1):5261. |
|
|
|