Comparison of readout segmented EPI and single-shot EPI diffusion weighted imaging in patients with breast cancer |
GUAN Wei ZHANG Yi DENG Ligang HAN Dan LI Jing YANG Zhenghan WANG Zhenchang YIN Hongxia |
Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China |
|
|
Abstract Objective To investigate the image quality different of readout segmented echo planar imaging (Rs-EPI) and single-shot echo planar imaging (Ss-EPI) diffusion weighted imaging (DWI) in patients with breast cancer. Methods Thirty-six patients with breast cancer performed MR scan in Beijing Friendship Hospital, Capital Medical University from March to August 2018 were retrospectively enrolled in this study. In all patients, Rs-EPI-DWI and Ss-EPI-DWI were performed. Two independent readers visually assessed lesion edge sharpness evaluation (ESE) and geometric distortion evaluation (GDE). Differences between two sequences were compared quantitatively by measuring the signal-to-noise ratio (SNR), contrast, contrast-to-noise ratio (CNR), and relative apparent diffusion coefficient (rADC). Results ESE, GDE, CNR, and rADC values showed a significant difference between Rs-EPI-DWI and Ss-EPI-DWI (P < 0.01). There was no statistically significant difference in SNR and contrast values between the two sequences (P > 0.05). Conclusion In breast cancer, Rs-EPI-DWI provids significantly higher image quality than Ss-EPI-DWI.
|
|
|
|
|
[1] Partridge SC,Nissan N,Rahbar H,et al. Diffusion-weighted breast MRI:Clinical applications and emerging techniques [J]. J Magn Reson Imaging,2017,45(2):337-355.
[2] Bogner W,Gruber S,Pinker K,et al. Diffusion-weighted MR for differentiation of breast lesions at 3.0 T:how does selection of diffusion protocols affect diagnosis? [J]. Radiology,2009,253(2):341-351.
[3] Kim EJ,Kim SH,Kang BJ,et al. Diagnostic value of breast MRI for predicting metastatic axillary lymph nodes in breast cancer patients:diffusion-weighted MRI and conventional MRI [J]. Magn Reson Imaging,2014,32(10):1230-1236.
[4] Ertas G,Onaygil C,Bugdayci O,et al. Dual-Phase ADC Modelling of Breast Masses in Diffusion-Weighted Imaging:Comparison with Histopathologic Findings [J]. Eur J Breast Health,2018,14(2):85-92.
[5] Arlinghaus LR,Welch EB,Chakravarthy AB,et al. Motion correction in diffusion-weighted MRI of the breast at 3T [J]. J Magn Reson Imaging,2011,33(5):1063-1070.
[6] Akin Y,Ugurlu MU,Kaya H,et al. Diagnostic Value of Diffusion-weighted Imaging and Apparent Diffusion Coefficient Values in the Differentiation of Breast Lesions,Histpathologic Subgroups and Correlation with Prognostic Factors using 3.0 Tesla MR [J]. J Breast Health,2016,12(3):123-132.
[7] Wu W,Miller KL. Image formation in diffusion MRI:A review of recent technical developments [J]. J Magn Reson Imaging,2017,46(3):646-662.
[8] Wisner DJ,Rogers N,Deshpande VS,et al. High-Resolution Diffusion-Weighted Imaging for the Separation of Benign From Malignant BI-RADS 4/5 Lesions Found on Breast MRI at 3T [J]. J Magn Reson Imaging,2014,40(3):674-681.
[9] Koyasu S,Iima M,Umeoka S,et al. The clinical utility of reduced-distortion readout-segmented echo-planar imaging in the head and neck region:initial experience [J]. Eur Radiol,2014,24(12):3088-3096.
[10] Thian YL,Xie WY,Porter DA,et al. Readout-segmented Echo-planar Imaging for Diffusion-weighted Imaging in the Pelvis at 3T-A Feasibility Study [J]. Acad Radiol,2014,21(4):531-537.
[11] Bogner W,Pinker-Domenig K,Bickel H,et al. Readout-segmented Echo-pIanar Imaging Improves the Diagnostic Performance of Diffusion-weighted MR Breast Examinations at 3.0 T [J]. Radiology,2012,263(1):64-76.
[12] 郗艳,刘慧,姚伟武,等.Rs-EPI与Ss-EPI在头及膝关节3T弥散成像中的对照研究[J].中国医学计算机成像杂志,2016,22(1):49-54.
[13] 许春苗,袁军辉,陈学军,等.比较3.0TMRI读出方向上的分段扩散成像技术与平面回波扩散加权成像技术对鼻咽癌的诊断价值[J].中华放射学杂志,2016,50(8):586-589.
[14] Kim YJ,Kim SH,Kang BJ,et al. Readout-Segmented Echo-Planar Imaging in Diffusion-Weighted MR Imaging in Breast Cancer:Comparison with Single-Shot Echo-Planar Imaging in Image Quality [J]. Korean J Radiol,2014,15(4):403-410.
[15] 费莹,许建铭,沈玉英,等.分段读出扩散加权成像序列ADC值在乳腺良恶性肿瘤鉴别诊断中的价值[J].中国现代医药杂志,2016,18(8):9-11.
[16] American College of Radiology (ACR). MRI quality control manual 2015[D]. Reton,VA:ACR; 2015.
[17] 尹红霞,杨娉娉,刘雅文,等.MRI设备中心频率和发射增益稳定性检测及处置界限建立[J].中国医学影像技术,2017,33(8):1260-1263.
[18] 刘雅文,尹红霞,杨娉娉,等.MRI设备临床质量控制流程和制度的现状与发展趋势[J].中国医学影像技术,2017, 33(11):1615-1619.
[19] Moon WJ. Measurement of signal-to-noise ratio in MR imaging with sensitivity encoding [J]. Radiology,2007, 243(3):908-909.
[20] Arturo C?魨?親rdenas-Blanco,Tejos C,Irarrazaval P,et al. Noise in magnitude magnetic resonance images [J]. Concepts in Magnetic Resonance Part A,2010,32A(6):409-416. |
|
|
|