Dual-phase CT imaging study in rabbit liver with low-dose contrast agent and low-kV |
ZHANG Jinling1 XIAO Xigang1▲ YUAN Biao2 |
1.Department of CT, the First Hospital Affiliated to Harbin Medical University, Heilongjiang Province, Harbin 150001, China;
2.Department of Radiology, Changsha Central Hospital, Hu′nan Province, Changsha 410000, China |
|
|
Abstract Objective To investigate the feasibility of dual-phase CT enhanced imaging of rabbit liver in low-kV scan mode with low concentration contrast agent. Methods Fourteen rabbits (3.5-4.0 months age, weighing 2.0-2.5 kg) were selected and divided into groups A, B and C according to the scanning mode, and the tube voltages were 120, 100 and 80 kV, respectively, the contrast medium concentration was 350 mgI/mL in group A and 270 mgI/mL in group B and C. All subjects underwent dual-phase enhanced CT scanning according to the scanning conditions of group A-C. The CT value and noise of portal vein, abdominal aorta, abdominal wall muscle and liver parenchyma were measured, and the contrast noise ratio (CNR) and signal-to-noise ratio (SNR) were calculated. All images were subjectively scored by two experienced radiologists. Results There was significant difference in effective radiation dose among the three groups (P < 0.05). There was no significant difference in abdominal aorta CT value, CNR, SNR, hepatic parenchyma CT value and CNR between the three groups during arterial phase (P > 0.05), but there was significant difference in hepatic parenchyma SNR and noise between the three groups (P < 0.05), and the noise in group C was higher than that in group A and B; the difference in abdominal aorta CT value between group B and C was significant (P < 0.05); there was a systematic difference in noise between the two groups (P < 0.05). There was no significant difference in CT value of hepatic parenchyma and CNR, SNR and noise of abdominal aorta, portal vein and hepatic parenchyma among the three groups during portal vein phase (P > 0.05); there was significant difference in CT value of portal vein and abdominal aorta among the three groups (P < 0.05); CT values of portal vein in group A and B were compared with group C, group C was higher than group A and group B, the difference was statistically significant (P < 0.05); group B had higher CT value of abdominal aorta compared with group A, the difference was statistically significant (P < 0.05). There were no significant differences in the subjective scores of contrast, noise, sharpness and overall in the three groups (P > 0.05), but the contrast and noise of group A was higher than that of group C, and the differences were statistically significant (P < 0.05). There were no significant differences in the subjective scores of contrast, noise, sharpness, and overall between the three groups in the portal vein phase, and there was no significant difference between the two groups (P > 0.05). Conclusion Low-concentration contrast agent combined with low-kV scanning can reduce the effective radiation dose, increase the vascular CT value, combined with ASIR reconstruction technology, can improve the image quality, meet the diagnostic needs, and provide a theoretical basis for clinical liver enhancement scanning.
|
|
|
|
|
[1] Schweiger MJ,Chambers CE,Davidson CJ,et al. Prevention of contrast induced nephropathy:recommendations for the high risk patient undergoing cardiovascular procedures [J]. Catheter Cardio Inte,2007,69(1):135-140.
[2] Weisbord SD,Palevsky PM. Radiocontrast-induced acute renal failure [J]. J Intensive Care Med,2005,20(2):63-75.
[3] Wong GT,Irwin MG. Contrast-induced nephropathy [J]. Brit J anaesth,2007,99(4):474-483.
[4] Davidson C,Stacul F,McCullough PA,et al. Contrast medium use [J]. Am J Cardiol,2006,98(6):42-58.
[5] Call J,Sacrinty M,Applegate R,et al. Automated contrast injection in contemporary practice during cardiac catheterization and PCI:Effects on contrast-induced nephropathy [J]. J Invasive Cardiol,2006,18(10):469.
[6] Thomsen HS. Recent hot topics in contrast media [J]. Eur Radiol,2011,21(3):492-495.
[7] 谢继承,陈盈,周亚敏,等.HDCT能谱技术提高肝硬化门静脉血管成像图像质量的价值研究[J].医学影像学杂志,2013,23(4):532-534.
[8] Zheng M,Liu Y,Wei M,et al. Low concentration contrast medium for dual-source computed tomography coronary angiography by a combination of iterative reconstruction and low-tube-voltage technique: Feasibility study [J]. Eur J of Radiol,2014,83(2):e92-e99.
[9] Zo′o M,Hoermann M,Balassy C,et al. Renal safety in pediatric imaging: randomized, double-blind phase IV clinical trial of iobitridol 300 versus iodixanol 270 in multidetector CT [J]. Pediatr Radiol,2011,41(11):1393-1400.
[10] Zhang W,Li M,Zhang B,et al. CT Angiography of the Head-and-Neck Vessels Acquired with Low Tube Voltage,Low Iodine,and Iterative Image Reconstruction:Clinical Evaluation of Radiation Dose and Image Quality [J]. PLoS One,2013,8(12):e81-e86.
[11] Marin D,Nelson RC,Schindera ST,et al. Low-Tube-Voltage,High-Tube-Current Multidetector Abdominal CT:Improved Image Quality and Decreased Radiation Dose with Adaptive Statistical Iterative Reconstruction Algorithm—Initial Clinical Experience [J]. Radiology,2010, 254(1):145-153.
[12] 赵丽琴,贺文,陈疆红,等.兔肝动脉碘分数与肝动脉指数的相关性[J].中国医学影像技术,2011,27(12):2381-2384.
[13] 赵丽琴,贺文,李剑颖.能谱CT对门静脉成像质量影响的研究[J].CT理论与应用研究,2011,20(3):383-390.
[14] Nakaura T,Nakamura S,Maruyama N,et al. Low Contrast Agent and Radiation Dose Protocol for Hepatic Dynamic CT of Thin Adults at 256–Detector Row CT:Effect of Low Tube Voltage and Hybrid Iterative Reconstruction Algorithm on Image Quality [J]. Radiology,2012, 264(2):445-454.
[15] McCullough PA,Brown JR. Effects of intra-arterial and intravenous iso-osmolar contrast medium (iodixanol) on the risk of contrast-induced acute kidney injury:a Meta-analysis [J]. Cardiorenal Med,2011,1(4):220-234.
[16] H?覿ussler MD. Safety and patient comfort with iodixanol:A postmarketing surveillance study in 9515 patients undergoing diagnostic CT examinations [J]. Acta Radiol,2010,51(8):924-933.
[17] Palena LM,Sacco ZD,Brigato C,et al. Discomfort assessment in peripheral angiography:Randomized clinical trial of iodixanol 270 versus ioversol 320 in diabetics whit critical limb ischemia [J]. Catheter Cardio Inte,2014,84(6):1019-1025.
[18] Weiland FL,Marti-Bonmati L,Lim L,et al. Comparison of patient comfort between iodixanol and iopamidol in contrast-enhanced computed tomography of the abdomen and pelvis:a randomized trial [J]. Acta Radiol,2014,55(6):715-724.
[19] 周泽旺,张昌政,郑瑛琪,等.能谱CT单能量成像结合低浓度对比剂在门静脉成像的应用价值[J].中国医疗设备,2017,32(5):87-90.
[20] 张龙敏,刘爱连,刘义军,等.低浓度对比剂能谱CT单能量成像对提高门静脉图像质量的研究[J].放射学实践,2015,30(4):360-363. |
|
|
|