Systemic retroversion for development of tumorous treatment |
PENG Jianqiao Matthew1 LIN Yepeng2 YANG Weiwen3 |
1.Department of Join Surgery in Sports Medicine, Affiliated Jiangmen Hospital of Traditional Chinese Medicine, Jinan University Jiangmen Institute of Orthopedics, Guangdong Province, Jiangmen 529031, China;
2.Department of Orthopedics Trauma, Foshan Shanshui Drstrict People’s Hospital, Guangdong Province, Foshan 528200, China;
3.National Institute of Respiration, the First Affiliated Hospital of Guangzhou Medical University, Guangdong Province, Guangzhou 510120, China |
|
|
Abstract Previously, temperature check only reaches a body surface but not organic scope, and temperature is controlled only by vista but not intelligent quantization. Harmless temperature measurement is minimal or none invasive in advantage, how to monitor thermotherapy control by examining temperature accurately as to take advantage of thermotherapy is a hot topic. This paper summarizes some ideas and methods of tumor hyperthermia by reviewing the latest literature on tumor hyperthermia. Precise hyperthermia for tumors, for example, can be planned through advanced technologies such as proton resonance frequency shift-magnetic resonance thermal imaging, magnetic resonance-guided, laser-induced thermal therapy, and Sigma-HyperPlan. This panper depicts the natural regulation of thermal treatment is by historically reviewing the developing procedure about thermal treatment, the principle and solution of thermal treatment in past is well learnt, and critical thinking is provided by now.
|
|
|
|
|
[1] Scipione R,Anzidei M,Bazzocchi A,et al. HIFU for Bone Metastases and other Musculoskeletal Applications [J]. J Semin Intervent Radio,2018,35(4):261-267.
[2] Khokhlova TD,Canney MS,Lee D,et al. Magnetic resonance imaging of boiling induced by high intensity focused ultrasound [J]. J Acoust Soc Am,2009,125:2420-2431.
[3] Chu W,Staruch RM,Pichardo S,et al. Magnetic resonance-guided high-intensity focused ultrasound hyper thermia for recurrent rectal cancer:MR thermometry evaluation and preclinical validation [J]. Int J Radiat Oncol Biol Phys,2016,95:1259-1267.
[4] Demura K,Morikawa S,Murakami K,et al. An easy-to-use microwave hyperthermia system combined with spatially resolved MR temperature maps:phantom and animal studies [J]. J Surg Res,2006,135(1):179-186.
[5] Keyserlingk JR,Ahlgren PD,Yu E,et al. Infrared Imaging of the Breast: Initial Reappraisal Using High-Resolution Digital Technology in 100 Successive Cases of Stage I and II Breast Cancer [J]. Breast J,1998,4(4):245-251.
[6] Etehadtavakol M,Ng EY,Gheissari N,et al. Using shape contexts method for registration of contra lateral breasts in thermal images [J]. World J Clin Oncol,2014,5(5):1055-1059.
[7] Jeong J,Park K,Lee C. Design of Cavity-Backed Bow-Tie Antenna with Matching Layer for Human Body Application [J]. Sensors(Basel),2019,19(18):4015.
[8] 皮钊逢.用于人体温度测量微波辐射计天线的研究[D].武汉:华中科技大学:2015.
[9] Lazebnik M,Popovic D,Mccartney L,et al. A large-scale study of the ultrawideband microwave dielectric properties of normal,benign and malignant breast tissues obtained from cancer surgeries [J]. Physics Med Bio,2007,52(20):6093-6115.
[10] Xia L,Zheng R,Xu Y,et al. Incidence and mortality of primary bone cancers in China,2014 [J]. Chin J Cancer Res,2019,31(1):135-143.
[11] Barter S,Hicks I. Electrical impedance imaging of the breast(TranScan TS 2000):initial UK experience [J]. Breast Cancer Res,2000:A11(2000).
[12] Rolfe R,Shea C,Murphy P,et al. Investigating the mechanistic basis of biomechanical input controlling skeletal development:exploring the interplay with Wnt signalling at the joint [J]. Philos Trans R Soc Lond B Biol Sci,2018, 373(1759):20170329.
[13] Latikka J,Eskola H. The Resistivity of Human Brain Tumours In Vivo [J]. An Biomed Eng,2019,19(3):e0703302.
[14] 蔡华,尤富生,史学涛,等.离体猪肝组织温度的电阻抗成像监测研究[J].医疗卫生装备,2012,33(2):5-7.
[15] 李俊来,李昶田,贾红,等.热层析成像温度分布在乳腺疾病中的诊断价值[J].中国医学影像学杂志,2014,22(4):241-243.
[16] 赵毅斌.乳腺钼靶X线的摄影方法及影响摄影图像质量因素分析[J].中国医学人文(学术版),2016,6(12):1-3.
[17] 石东兵.基于声传输特性的超声测温方法研究[D].长沙:湖南师范大学,2015.
[18] Chen BT,Shieh J,Huang CW,et al. Ultrasound thermal mapping based on a hybrid method combining physical and statistical models [J]. Ultrasound Med Biol,2014,40(1):115-129.
[19] Park S,Hwang J,Park J,et al. Application of Ultrasound Thermal Imaging for Monitoring Laser Ablation in Ex Vivo Cardiac Tissue [J]. Lasers Surg Med,2019,13(6):35-43.
[20] Choi M,Seo H,Park B,et al. Effects of picosecond laser on the multi-colored tattoo removal using Hartley guinea pig:A preliminary study [J]. PLoS One,2018,13(9):e0203370.
[21] Bloembergen N,Purcell EM,Pound RV,et al. Relaxation effects in nuclear magnetic resonance absorption [J]. Phys Rev,1948,73:679.
[22] Han M,Rieke V,Scott SJ,et al. Quantifying temperature-dependent T1 changes in cortical bone using ultrashort echo-time MRI [J]. Magn Reson Med,2015,74:1548-1555.
[23] Stauffer PR,Snow BW,Rodrigues DB,et al. Non-Invasive Measurement of Brain Temperature with Microwave Radiometry [J]. Neuroradiology,2014(4):12-16.
[24] Hindman JC. Proton resonance shift of water in the gas and liquid states [J]. Chem Phys,1966,44(12):4582-4592.
[25] De PJ. Noninvasive MRI thermometry with the proto resonance frequency method:study of susceptibility effects [J]. Magn Reson Med,1995,34:359-367.
[26] Waldemar W,Ralf B,Michael H,et al. Three-dimensional monitoring of small temperature changes of therapeutic hyperthermia using MR [J]. JMRI,1998,8:165-174.
[27] Ahrar K,Stafford RJ. Magnetic resonance imaging-guided laser ablation of bone tumors [J]. Tech Vasc Interv Radiol,2011,14(3):177-182.
[28] Jonathan SV,Grissom WA,Volumetric MR. Thermometry using a three-dimensional stack-of-stars echo-planar imaging pulse sequence [J]. Mag Reson Med,2018,79(4):2003-2013.
[29] Bever JTD,Odeen H,Hofstetter LW,et al. Simultaneous MR thermometry and acoustic radiation force imaging using interleaved acquisition[J]. Mag Reson Med,2018,79(3):1515-1524.
[30] Freeman NJ,Odéen H,Parker DL. 3D-specific absorption rate estimation from high-intensity focused ultrasound sonications using the Green’s function heat kernel [J]. Med Phys,2018,45(7):3109-3119.
[31] Patel PD,Patel NV,Davidson C,et al. The Role of MRgLITT in Overcoming the Challenges in Managing Infield Recurrence After Radiation for Brain Metastasis [J]. Neurosurgery,2016,79:S40-S58.
[32] Kerenyi A,Kelen D,Faulkner S,et al. Systemic effects of whole-body cooling to 35°C,33.5°C and 30°C in a piglet perinatal asphyxia model:implications for therapeutic hypothermia [J]. Pediatr Res,2012,71(5):573-582.
[33] Lozano A,Ayes J,Compton L,et al. Determining the thermal characteristics of breast cancer based on high-resolution infrared imaging,3D breast scans,and magnetic resonance imaging [J]. Sci Rep,2020,10:10105.
[34] Peng MJ,Cao X,Chen HY,et al. Intralesional curettage versus prosthetic replacement for bone tumors-a finite element analysis case of limb salvage simulation in biomechanics [J]. Comput Methods Programs Biomed,2021:105775. |
|
|
|