Research progress of iterative model reconstruction in CT angiography
AN Zichen1 XIAO Xigang1 ZHANG Jinling1 LYU Yahui2 LI Maotong1
1.Department of Radiology, the First Affiliated Hospital of Harbin Medical University, Heilongjiang Province, Harbin 150001, China;
2.Department of Radiology, Harbin Second People′s Hospital, Heilongjiang Province, Harbin 150056, China
Abstract:Iterative model reconstruction (IMR) technology is a new type of iterative reconstruction algorithm. Compared with the traditional filtered back projection and hybrid iterative algorithm, it performs better in reducing noise and improving image quality. Application of IMR reconstruction can reduce the radiation dose and ensure the image quality. In this paper, the clinical application progress of IMR technology in CT angiography of various parts is reviewed, and a simple estimation is made to provide reference for related research.
[1] Cai W,Hu C,Hu S,et al. Feasibility study of iterative model reconstruction combined with low tube voltage,low iodine load,and low iodine delivery rate in craniocervical CT angiography [J]. Clin Radiol,2018,73(2):217.e1-e6.
[2] Zhang W,Li M,Zhang B,et al. CT Angiography of the head-and-neck vessels acquired with low tube voltage,low iodine,and iterative image reconstruction:clinical evaluation of radiation dose and image quality [J]. PLoS One,2013,8(12):e81486.
[3] No?觕l PB,K?觟hler T,Fingerle AA,et al. Evaluation of an iterative model–based reconstruction algorithm for low-tube-voltage (80 kVp) computed tomography angiography [J]. J Med Imaging(Bellingham),2014,1(3):033501.
[4] Paruccini N,Villa R,Pasquali C,et al. Evaluation of a commercial Model Based Iterative reconstruction algorithm in computed tomography [J]. Phys Med,2017,41:58-70.
[5] Hou P,Feng X,Liu J,et al. Low tube voltage and iterative model reconstruction in follow-up ct angiography after thoracic endovascular aortic repair:ultra-low radiation exposure and contrast medium dose [J]. Acad Radiol,2018, 25(4):494-501.
[6] Cheng B,Xing H,Du L,et al. Impact of iterative model reconstruction combined with dose reduction on the image quality of head and neck CTA in children [J]. Sci Rep,2018,8(1):12613.
[7] 鲁晓辰.256排多层螺旋CT全模型迭代算法对下肢动脉造影低剂量成像的临床应用研究[D].大连:大连医科大学,2016.
[8] 蒋骏,黄美萍,雷益,等.全模型迭代重建技术在心脏CT成像中应用的实验研究[J].中华放射学杂志,2015,49(6):473-477.
[9] Khawaja RDA,Singh S,Blake M,et al. Ultra-low dose abdominal MDCT:Using a knowledge-based Iterative Model Reconstruction technique for substantial dose reduction in a prospective clinical study [J]. Eur J Radiol,2015,84(1):2-10.
[10] 蔡武,胡春洪,王希明,等.“四低”联合自动管电流调节和全模型迭代重建技术在头颈部CT血管成像中的应用[J].中华医学杂志,2018,98(1):30-35.
[11] Niesten JM,van der Schaaf IC,Vos PC,et al. Improving head and neck CTA with hybrid and model-based iterative reconstruction techniques [J]. Clin Radiol,2015,70(11):1252-1259.
[12] 王君玲,许乙凯,周芳,等.全模型迭代重建技术在头颈部血管成像中的应用[J].科学技术与工程,2016,16(35):34-39.
[13] Hu MQ,Li M,Liu ZY,et al. Image quality evaluation of iterative model reconstruction on low tube voltage (80 kVp) coronary CT angiography in an animal study [J]. Acta Radiol,2016,57(2):170-177.
[14] Park CH,Lee J,Oh C,et al. The feasibility of sub-millisievert coronary CT angiography with low tube voltage,prospective ECG gating,and a knowledge-based iterative model reconstruction algorithm [J]. Int J Cardiovasc Imaging,2015,31(Suppl 2):197-203.
[15] Oda S,Weissman G,Vembar M,et al. Iterative model reconstruction:Improved image quality of low-tube-voltage prospective ECG-gated coronary CT angiography images at 256-slice CT [J]. Eur J Radiol,2014,83(8):1408-1415.
[16] Halpern EJ,Gingold EL,White H,et al. Evaluation of coronary artery image quality with knowledge-based Iterative Model Reconstruction [J]. Acad Radiol,2014,21(6):805-811.
[17] Laqmani A,Maximillian K,Butscheidt S,et al. CT Pulmonary Angiography at Reduced Radiation Exposure and Contrast Material Volume Using Iterative Model Reconstruction and iDose4 Technique in Comparison to FBP[J]. PLoS One,2016,11(9):e0162429.
[18] Hou P,Feng X,Liu J,et al. Low Tube Voltage and Iterative Model Reconstruction in follow-up CT angiography after thoracic endovascular aortic repair:ultra-low radiation exposure and contrast medium dose [J]. Acad Radiol,2018,25(4):494-501.
[19] Qin L,Ma ZP,Yan FH,et al. Iterative model reconstruction(IMR)algorithm for reduced radiation dose renal artery CT angiography with different tube voltage protocols [J]. Radiol Med,2018,123(2):83-90.
[20] Murphy KP,Crush L,Twomey M,et al. Model-based iterative reconstruction in ct enterography [J]. AJR Am J Roentgenol,2015,205(6):1173-1181.
[21] Nakamoto A,Kim T,Hori M,et al. Clinical evaluation of image quality and radiation dose reduction in upper abdominal computed tomography using model-based iterative reconstruction;comparison with filtered back projection and adaptive statistical iterative reconstruction [J]. Eur J Radiol,2015,84(9):1715-1723.
[22] 刘彬,高思喆,王传卓,等.低管电压联合全模型迭代重建技术在下肢动脉CTA中的应用[J].中国临床医学影像杂志,2018,29(9):660-663.
[23] 钱伟亮,丰川,周丹静,等.FBP、iDose4和IMR重建算法对低剂量双下肢CTA图像质量的影响[J].中国医学影像技术,2017,33(2):290-294.
[24] Oda S,Yoshimura A,Honda K,et al. CT Angiography in patients with peripheral arterial disease: effect of small focal spot imaging and iterative model reconstruction on the image quality [J]. Acad Radiol,2016,23(10):1283-1289.
[25] Li ZL,Li H,Zhang K,et al. Improvement of image quality and radiation dose of CT perfusion of the brain by means of low-tube voltage (70 kV) [J]. Eur Radiol,2014, 24(8):1906-1913.
[26] 张云.低剂量及极低剂量脑CT灌注成像联合全模型迭代重建算法在脑卒中诊断中的初步临床研究[D].苏州:苏州大学,2017.
[27] 黎佩君,黄飚,梁长虹,等.迭代重建算法CT灌注成像与CT血管造影在缺血性脑血管病中的诊断价值[J].中国医学影像学杂志,2013,21(12):881-885,890.
[28] Uchida M. High-quality three-dimensional computed tomography angiography of abdominal viscera with small focal spot,low tube voltage,and iterative model reconstruction technique [J]. Open J Radiol,2015,5(1):8-12.
[29] 周丹静,许建铭,姜彦,等.迭代模型重建技术在低剂量胸部CT双期增强扫描中的可行性[J].中国医学影像技术,2017,33(5):768-772.
[30] Park HJ,Lee JM,Jeong YK,et al. Comparison of knowledge-based iterative model reconstruction and hybrid reconstruction techniques for liver ct evaluation of hypervascular hepatocellular carcinoma [J]. J Comput Assist Tomogr,2016,40(6):863-871.
[31] Liu X,Chen L,Qi W,et al. Thin-slice brain CT with iterative model reconstruction algorithm for small lacunar lesions detection:Image quality and diagnostic accuracy evaluation [J]. Medicine (Baltimore),2017,96(51):e9412.
[32] Lukas L,Petr O,Jan B,et al. Sub-milliSievert ultralow-dose CT colonography with iterative model reconstruction technique [J]. Peer J,2016,4:e1883.
[33] Wu Y,Jiang Y,Han X,et al. Application of low-tube current with iterative model reconstruction on Philips Brilliance iCT Elite FHD in the accuracy of spinal QCT using a European spine phantom [J]. Quant Imaging Med Surg,2018,8(1):32-38.
[34] Wellenberg RH,Boomsma MF,van Osch JA,et al. Computed tomography imaging of a hip prosthesis using iterative model-based reconstruction and orthopaedic metal artefact reduction:a quantitative analysis [J]. J Comput Assist Tomogr,2016,40(6):971-978.
[35] Wellenberg RH,Boomsma MF,van Osch JA,et al. Low-dose CT imaging of a total hip arthroplasty phantom using model-based iterative reconstruction and orthopedic metal artifact reduction [J]. Skeletal Radiol,2017,46(5):623-632.