Abstract:Blood pressure is an important physiological index of the human body, in recent years, there has been an increasing demand for non-invasive, cuffless, and continuous blood pressure monitoring devices. A suitable model based on the characteristic parameters of pulse wave can be used to continuously estimate arterial blood pressure by measuring a series of characteristics of pulse such as pulse transmission time of arterial pulse wave. This paper first introduces the principle of blood pressure measurement based on the characteristic parameters of pulse wave, and summarizes the relevant measurement models, such as linear regression model, non-linear regression model, and neural network model, summarizes the research results, introduces the research status of the application of pulse wave technology in cardiovascular diseases, and finally analyzes its future development trend.
[1] Kearney PM,Whelton M,Reynolds K,et al. Global burden of hypertension:analysis of worldwide data [J]. Lancet,2005, 365(9455):217-223. [2] 中国心血管健康与疾病报告编写组.中国心血管健康与疾病报告2021概要[J].中国循环杂志,2022,37(6):553- 578. [3] 中国高血压防治指南修订委员会,高血压联盟(中国,中华医学会心血管病学分会中国医师协会高血压专业委员会,等.中国高血压防治指南(2018年修订版)[J]. 中国心血管杂志,2019,24(1):24-56. [4] Liang Y,Elgendi M,Chen Z,et al. An optimal filter for short photoplethysmogram signals [J]. Sci Data,2018,5(1):180076. [5] Hosanee M,Chan G,Welykholowa K,et al. Cuffless Single-Site Photoplethysmography for Blood Pressure Monitoring [J]. J Clin Med,2020,9(3):723. [6] Lee GH,Moon H,Kim H,et al. Multifunctional materials for implantable and wearable photonic healthcare devices [J]. Nat Rev Mater,2020,5(2):149-165. [7] Arnold N,Gori T,Schnabel RB,et al. Relation between Arterial Stiffness and Markers of Inflammation and Hemostasis- Data from the Population-based Gutenberg Health Study [J]. Sci Rep,2017,7(1):6346. [8] Prabhakar SK,Rajaguru H,Kim SH. Fuzzy-Inspired Photoplethysmography Signal Classification with Bio-Inspired Optimization for Analyzing Cardiovascular Disorders [J]. Diagnostics,2020,10(10):763. [9] Martin SL,Carek AM,Kim CS,et al. Weighing Scale-Based Pulse Transit Time is a Superior Marker of Blood Pressure than Conventional Pulse Arrival Time [J]. Sci Rep,2016,6:39273. [10] Nabeel PM,Jayaraj J,Mohanasankar S. Single-source PPG- based local pulse wave velocity measurement:a potential cuffless blood pressure estimation technique [J]. Physiol Meas,2017,38(12):2122-2140. [11] Liang Y,Chen Z,Ward R,et al. Hypertension Assessment via ECG and PPG Signals:An Evaluation Using MIMIC Database [J]. Diagnostics(Basel),2018,8(3):65. [12] Simjanoska M,Gjoreski M,Gams M,et al. Non-Invasive Blood Pressure Estimation from ECG Using Machine Learning Techniques [J]. Sensors,2018,18(4):1160. [13] Finnegan E,Davidson S,Harford M,et al. Features from the photoplethysmogram and the electrocardiogram for estimating changes in blood pressure [J]. Sci Rep,2023,13(1): 986. [14] Chandrasekhar A,Yavarimanesh M,Natarajan K,et al. PPG Sensor Contact Pressure Should Be Taken Into Account for Cuff-Less Blood Pressure Measurement [J]. IEEE Trans Biomed Eng,2020,67(11):3134-3140. [15] 张振强,陈真诚,顾爽,等.基于光电容积脉搏波的心血管多参数检测系统[J].科学技术与工程,2021,21(20):8383-8388. [16] 张畅,陈辉,郑秀娟.基于优化脉搏波特征的无袖带血压检测方法[J].电子测量技术,2021,44(24):1-7. [17] Haddad S,Boukhayma A,Caizzone A. Continuous PPG- Based Blood Pressure Monitoring Using Multi-Linear Regression [J]. IEEE J Biomed Health Inform,2022,26(5):2096-2105. [18] Sharifi I,Goudarzi S,Khodabakhshi MB. A novel dynamical approach in continuous cuffless blood pressure estimation based on ECG and PPG signals [J]. Artif Intell Med,2019, 97:143-151. [19] Yan J,Cai X,Zhu G,et al. A non-invasive blood pressure prediction method based on pulse wave feature fusion [J]. Biomed Signal Process Control,2022,74:103523. [20] 贺楚芳.基于PPG形态学的无创连续血压预测算法研究[D].北京:北京交通大学,2020. [21] 杨鹤标,龚文彦.基于卷积神经网络的反向传播算法改进[J].计算机工程与设计,2019,40(1):126-130. [22] Ismail S,Siddiqi I,Akram U. Heart rate estimation in PPG signals using Convolutional-Recurrent Regressor [J]. Comput Biol Med,2022,145:105470. [23] Wilkosz M,Szcz?誰sna A. Multi-Headed Conv-LSTM Network for Heart Rate Estimation during Daily Living Activities [J]. Sensors,2021,21(15):5212. [24] Jeong DU,Lim KM. Combined deep CNN-LSTM network- based multitasking learning architecture for noninvasive continuous blood pressure estimation using difference in ECG-PPG features [J]. Sci Rep,2021,11(1):13539. [25] Mahmud S,Ibtehaz N,Khandakar A,et al. A Shallow U- Net Architecture for Reliably Predicting Blood Pressure(BP)from Photoplethysmogram (PPG)and Electrocardiogram(ECG)Signals [J]. Sensors,2022,22(3):919. [26] Yao P,Xue N,Yin S,et al. Multi-Dimensional Feature Combination Method for Continuous Blood Pressure Measurement Based on Wrist PPG Sensor[J]. IEEE J Biomed Health Inform,2022,26(8):3708-3719. [27] Treebupachatsakul T,Boosamalee A,Shinnakerdchoke S,et al. Cuff-Less Blood Pressure Prediction from ECG and PPG Signals Using Fourier Transformation and Amplitude Randomization Preprocessing for Context Aggregation Network Training [J]. Biosensors,2022,12(3):159. [28] Brophy E,De Vos M,Boylan G,et al. Estimation of Continuous Blood Pressure from PPG via a Federated Learning Approach [J]. Sensors,2021,21(18):6311. [29] Schrumpf F,Frenzel P,Aust C,et al. Assessment of Non- Invasive Blood Pressure Prediction from PPG and rPPG Signals Using Deep Learning [J]. Sensors,2021,21(18):6022. [30] Liang Y,Chen Z,Ward R,et al. Hypertension Assessment Using Photoplethysmography:A Risk Stratification Approach [J]. J Clin Med,2018,8(1):12. [31] Sadad T,Bukhari SAC,Munir A,et al. Detection of Cardiovascular Disease Based on PPG Signals Using Machine Learning with Cloud Computing [J]. Comput Intell Neurosci,2022,2022:1672677. [32] Guo Y,Wang H,Zhang H,et al. Mobile Photoplethysmographic Technology to Detect Atrial Fibrillation [J]. J Am Coll Cardiol,2019,74(19):2365-2375.