Research on the advantages of 3D printing template compared with simple CT-guided 125I seeds implantation in recurrent and metastatic cancer of head and neck#br#
WANG Zeyang LIANG Yansong ZHANG Hongtao CAO Guohui LIU Zezhou GAO Zhen ZHAO Jinxin WANG Juan
Ward One, Department of Oncology, Hebei General Hospital, Hebei Province, Shijiazhuang 050051, China
Abstract:Objective To investigate the advantages of 3D printing template compared with simple CT-guided 125I seeds implantation in recurrent and metastatic cancer of head and neck. Methods A total of 99 patients (99 lesions) with recurrent and metastatic cancer of head and neck treated with 125I seeds in Hebei General Hospital from April 2015 to February 2019 were selected, according to whether 3D printing template was applied, they were divided into 3D printing template group (group A, 49 cases [49 lesions]) and simple CT guided group (group B, 50 cases [50 lesions]). The quality and efficacy of 125I seeds implantation were evaluated between two groups; CT scan times, operation time and single seed implantation time were compared between two groups; the target volume, seeds number and dosimetric parameters (D90, V90, V100, V150) before and after operation were compared between two groups; the incidence of complications in two groups were observed. Results There was no significant difference in the quality of 125I seeds implantation between two groups (P > 0.05). Two months after operation, there were no significant differences in local control rate and effective rate between two groups (P > 0.05). Three months after operation, there was no significant difference in local control rate between two groups (P > 0.05); the effective rate of group A was higher than that of group B, and the difference was statistically significant (P < 0.05). The operation time and single seed implantation time of group A were shorter than those of group B, and CT scan times were less than those of group B, and the differences were statistically significant (P < 0.05). There were no significant differences in target volume, seeds number, and dosimetric parameters in group A before and after operation (P > 0.05). There were no significant differences in target volume, seeds number, D90, and V90 in group B before and after operation (P > 0.05); after operation, V100 in group B was lower than that before operation, and V150 was higher than that before operation, and the differences were statistically significant (P < 0.05). After operation, there were no significant differences in target volume, seeds number, D90, V90, and V150 between two groups (P > 0.05); V100 in group A was higher than that in group B, and the differences were statistically significant (P < 0.05). The incidence of puncture pain in group A was lower than that in group B, and the difference was statistically significant (P < 0.05); there was no significant difference in the incidence of hoarseness between two groups (P > 0.05). Conclusion Compared with simple CT guidance, 3D printing template can shorten the operation time, reduce the number of scans, reduce the incidence of complications, and improve the efficacy to a certain extent.
王泽阳 梁岩松 张宏涛 曹国辉 刘泽洲 高贞 赵金鑫 王娟. 3D打印模板较单纯CT引导125I粒子植入头颈部复发转移癌优势研究[J]. 中国医药导报, 2021, 18(35): 105-109.
WANG Zeyang LIANG Yansong ZHANG Hongtao CAO Guohui LIU Zezhou GAO Zhen ZHAO Jinxin WANG Juan. Research on the advantages of 3D printing template compared with simple CT-guided 125I seeds implantation in recurrent and metastatic cancer of head and neck#br#. 中国医药导报, 2021, 18(35): 105-109.
[1] Lin L,Wang J,Jiang Y,et al. Interstitial 125I Seed Implantation for Cervical Lymph Node Recurrence after Multimodal Treatment of Thoracic Esophageal Squamous Cell Carcinoma [J]. Technol Cancer Res Treat,2015,14(2):201-207. DOI:10.7785/tcrt.2012.
[2] 佘华龙,陈凯.表皮生长因子受体酪氨酸激酶抑制剂联合125I放射性粒子植入治疗非小细胞肺癌的效果[J].中国医药导报,2020,17(8):121-124.
[3] 林介军,卢立杰,金小军,等.门脉内支架同步125I粒子条植入序贯经肝动脉化疗栓塞治疗原发性肝癌合并门脉癌栓的效果[J].中国医药导报,2018,15(17):85-88.
[4] 曹德东,尹竺晟,戈伟.125I粒子植入放射治疗联合含铂化疗方案治疗晚期非小细胞肺癌疗效及安全性的Meta分析[J].中国医药导报,2017,14(2):97-101.
[5] Zhang H,Yu H,Liang Y,et al. Preliminary investigation of computed tomography-guided iodine-125 seed implantation treatment efficacy in patients with iliac lymph nodes metastases [J]. J Cancer Res Ther,2019,15(4):801.
[6] Zhao J,Zhi Z,Zhang H,et al. Efficacy and safety of CT guided 125I brachytherapy in elderly patients with nonsmall cell lung cancer [J]. Oncol Lett,2020,20(1):183-192.
[7] Jiang Y,Ji Z,Guo F,et al. Side effects of CT-guided implantation of 125I seeds for recurrent malignant tumors of the head and neck assisted by 3D printing non co-planar template [J]. Radiation Oncology,2018,13(1):18.
[8] Wang J,Zhang F,Guo J,et al. Expert consensus workshop report:Guideline for three-dimensional printing template-assisted computed tomography-guided 125I seeds interstitial implantation brachytherapy [J]. J Cancer Res Ther,2017, 13(4):607-612.
[9] 高贞,张宏涛,王娟,等.3D打印模板与徒手穿刺125I粒子植入治疗浅表转移癌剂量学对比分析[J].中华医学杂志,2019,99(47):3694-3698.
[10] 梁岩松,王娟,张宏涛,等.模板固定在3D打印模板引导粒子植入头颈部转移癌的重要作用[J].介入放射学杂志,2018,27(8):745-749.
[11] 中华医学会放射肿瘤学分会,中国医师学会放射治疗专业委员会,中国抗癌协会肿瘤微创治疗分会粒子治疗学组,等.CT引导放射性125I粒子组织间永久植入治疗肿瘤专家共识[J].中华医学杂志,2017,97(15):1132-1139.
[12] 王俊杰,柴树德,郑广钧,等.3D打印模板辅助CT引导放射性125I粒子植入治疗肿瘤专家共识[J].中华放射医学与防护杂志,2017,37(3):161-170.
[13] 张颖,林琦,袁苑,等.3D打印个体化模板联合CT引导125I粒子植入治疗恶性肿瘤质量评价[J].山东大学学报:医学版,2016,54(11):44-50.
[14] Keyes M,Morris WJ,Spadinger I,et al. Radiation oncology and medical physicists quality assurance in British Columbia Cancer Agency Provincial Prostate Brachytherapy Program [J]. Brachytherapy,2013,12(4):343-355.
[15] 张海利,董桂兰,刘丽丽,等.阿帕替尼治疗多线化疗后复发的广泛期小细胞肺癌的效果及对患者生存的影响[J].中国医药导报,2019,16(26):100-103.
[16] Therasse P,Arbuck SG,Eisenhauer EA,et al. New guidelines to evaluate the response to treatment in solid tumors. European organization for research and treatment of cancer,national cancer institute of the united states,National Cancer Institute of Canada [J]. J Natl Cancer Inst,2000,92:205-216.
[17] Rembowska AME,Cook M,Hoskin PJ,et al. The stepping source dosimetry system as an extension of the manchester system [J]. Radiother Oncol,1996,39(39):25. DOI:10.106/0167-8140(96)87900-X.
[18] 王娟,张宏涛,于慧敏.放射性粒子植入治疗技术动态剂量验证的意义[J].中华医学杂志,2018,98(23):1810-1812. DOI:10.3760/cma.j.issn.0376-2491.2018.23.002.
[19] Hongtao Z,Xuemin D,Huimin Y,et al. Dosimetry study of three-dimensional print template-guided precision 125I seed implantation [J]. J Cancer Res Ther,2016,12(2):C159-C162.
[20] Liang Y,Wang Z,Zhang H,et al. Three-dimensional-printed individual template-guided 125I seed implantation for the cervical lymph node metastasis:A dosimetric and security study [J]. J Cancer Res Ther,2018,14(1):30 -35.
[21] 邓秀文,吉喆,姜玉良,等.光学导航联合3D打印模板辅助125I粒子植入治疗头颈复发癌的剂量评估[J].中华放射医学与防护杂志,2021,41(1):3-8.
[22] 张国昊,黄明伟,郑磊,等.数字化外科技术在125I粒子植入治疗头颈深部肿瘤中的应用[J].中华放射医学与防护杂志,2021,41(1):14-18.
[23] 张强,郝延璋.125I放射性粒子植入在肿瘤综合治疗中的应用现状[J].中国医药科学,2021,11(2):62-64,90. DOI:10.3969/j.issn.2095-0616.2021.02.018.
[24] 陈文会,江旭,杨继金,等.CT引导介入操作中患者有效辐射剂量的研究[J].介入放射学杂志,2012,21(7):570-573. DOI:10.3969/j.issn.1008-794X.2012.07.010.